Operational and investment costs increase due to aging of the network, increasing the failure rate, leakage and the water demand, new investments and energy consumption. Several methods and tools with different initial investment and operating costs are proposed for reducing water losses in the related literature. The aim of this study is to make detailed evaluations within the framework of economic components for effective and sustainable water loss management and provide a reference for further studies. The most important advantage is that there has not been a detailed assessment and discussion in this context within the framework of economic analysis and the economic leakage level. The methods and tools for reducing the water losses such as district metered areas, passive leakage control, active leakage control, pressure management, pipe management and network renewal methods, were evaluated economically and discussed. The most important issues in water loss management are the definition of the economic leakage level and the cost components that are the maintenance and break repair, methods applied to detect and control the leaks and automation systems for monitoring, control and data transfer. Moreover, the priority, suitability, applicability and economic impact of the methods should be considered to decide the methods for more efficient use of resources.

Keywords


N.W.C. (NWC). (1980). Leakage control policy and practice, NWC Technical Working Group on Waste of Water Publication, London.
Agathokleous, A. and Christodoulou, S. (2017). "Component-holistic condition assessment of water distribution networks", Journal of Water Supply: Research and Technology, AQUA, 64(7), 509-519.
Al-Aghbar, A. (2005). Automated selected trenchless technology for the rehabilitation of water mains, M.Sc. Thesis, Concordia University, Canada.
Al-Ghamdi, A.S. (2011). "Leakage-pressure relationship and leakage detection in intermittent water distribution systems", Research and Technology, AQUA, 60(3), 178-183.
AL-Washali, T., Sharma, S. and Kennedy, M. (2016). "Methods of assessment of water losses in water supply systems: A review", Water Resources Management, 30(14), 4985-5001.
Al-Zahrani, M. Abo-Monasar, A. and Sadiq, R. (2016). "Risk-based prioritization of water main failure using fuzzy synthetic evaluation technique", Journal of Water Supply: Research and Technology, AQUA, 65(2), 145-161.
Alvisi, S., Luciani, C. and Franchini, M. (2019). "Using water consumption smart metering for water loss assessment in a DMA: A case study", Urban Water Journal, 18(1), 77-83.
Berardi, L., Laucelli, D.B., Simone, A., Mazzolani, G. and Giustolisi, O. (2016). "Active leakage control with WDNetXL", Procedia Engineering, 154, 62-70.
Cabral, M., Loureiro, D., Almeida, M.D.C. and Covas, D., (2019). "Estimation of costs for monitoring urban water and wastewater networks", Journal of Water Supply: Research and Technology, AQUA, 68(2), 87-97.
Cabrera, E., Pardo, M.A. and Arregui, F.J. (2013). "Tap water costs and service sustainability, A close relationship", Water Resources Management, 27(1), 239-253.
Campbell, E., Izquierdo, J., Montalvo, I. and Pérez-García, R. (2016). "A novel water supply network sectorization methodology based on a complete economic analysis, including uncertainties", Water (Switzerland), 8(5), 179.
Candelieri, A., Soldi, D. and Archetti, F. (2015). "Cost-effective sensors placement and leak localization, The Neptun pilot of the ICeWater Project.", Journal of Water Supply: Research and Technology, AQUA, 64(5), 567-582.
Charalambous, B. and Kanellopoulou, S. (2010). "Applied pressure management techniques to reduce and vontrol leakage", Proceedings of the IWA International Specialised Conference ‘Water Loss 2010’, 1-12.
Christodoulou, S. and Deligianni, A. (2009). "A neurofuzzy decision framework for the management of water distribution networks", Water Resources Management, 24, 139-156.
Creaco, E. and Walski, T. (2017). "Economic analysis of pressure control for leakage and pipe burst reduction’, Journal of Water Resources Planning and Management, 143(12), 1-11.
Deidda, D., Sechi, G.M. and Zucca, R. (2014). "Finding economic optimality in leakage reduction: A cost-simulation approach for complex urban supply systems’, Procedia Engineering, 70, 477-486.
De Paola, F., Galdiero, E. and Giugni, M. (2016). "A jazz-based approach for optimal setting of pressure reducing valves in water distribution networks", Engineering Optimization, 48(5), 727-739.
Di Nardo, A., Di Natale, M., Giudicianni, C., Santonastaso, G.F., Tzatchkov, V. and Varela, J.M.R. (2017). "Economic and energy criteria for district meter areas design of water distribution networks", Water (Switzerland), 9(7), 1-13.
Fallis, P., Hübschen, K., Oertle, E., Ziegler, D., Klingel, P., Baader, J., Trujillo, R. and Laures, C. (2011). Guidelines for water loss reduction, Eschborn, Germany: Deutsche Gesellschaft für International Zusammenarbeit (GIZ), Germany, p. 236.
Fanner, P., Thornton, J., Liemberger, R. and Sturm, R. (2007). "Evaluating water loss and planning loss reduction strategies", AWWA Research Foundation, AWWA, Denver, USA; IWA, London, UK.
Fanner, P. and Lambert, A. (2009). "Calculating SRELL with pressure management, active leakage control and leak run-time options, with confidence limits", Proceedings of WaterLoss 2009, IWA International Conference, IWA Publishing, 373-380.
Fantozzi, M. (2006). "Some international experiences in promoting the recent advances in practical leakage management", Water Practice and Technology, 1(2), 1-10.
Farley, M., Wyeth, G., Ghazali, Z.B.M., Istandar, A., Sigh, S. (2008). "The manager’s non-revenue water handbook, A guid to understanding water losses", Ranhill Utility Bernhad and United States Agency for International Development (USAID), Washington DC.
Farley, M. and Liemberger, R. (2005). "Developing a non-revenue water reduction strategy: Planning and implementing the strategy", Water Science and Technology: Water Supply, 15(1), 41-50.
Farley, M. and Trow, S. (2003). A practitioner's guide to assessment, monitoring and control, IWA Publishing, ISBN 9781780402642, UK, p. 296.
Ferrari, G. and Savic, D. (2015). "Economic performance of DMAs in water distribution systems", Procedia Engineering, 119(1), 189-195.
Fontana, N., Giugni, M., Glielmo, L., Marini, G. and Zollo, R. (2018). "Real-time control of pressure for leakage reduction in water distribution network: Field experiments", Journal of Water Resources Planning and Management, 144(3), 1-12.
Francisque, A., Tesfamariam, S., Kabir, G., Haider, H., Reeder, A. and Sadiq, R. (2017). "Water mains renewal planning framework for small to medium sized water utilities: A life cycle cost analysis approach", Urban Water Journal, 14(5), 493-501.
Ghorbanian, V., Guo, Y. and Karney, B. (2016). "Field data-based methodology for estimating the expected pipe break rates of water distribution systems", Journal of Water Resources Planning and Management, 142(10), 1-11.
Giustolisi, O., Laucelli, D. and Savic, D.A. (2006). "Development of rehabilitation plans for water mains replacement considering risk and cost-benefit assessment", Civil Engineering and Environmental Systems, 23(3), 175-190.
Gomes, R., Marques, A.S.A. and Sousa, J. (2013). "District metered areas design under different decision makers’ Options: Cost analysis", Water Resources Management, 27(13), 4527-4543.
Gomes, R., Marques, A.S. and Sousa, J. (2011). "Estimation of the benefits yielded by pressure management in water distribution systems", Urban Water Journal, 8(2), 65-77.
Haider, H., Al-Salamah, I.S., Ghazaw, Y.M., Abdel-Maguid, R.H., Shafiquzzaman, M. and Ghumman, A.R. (2019). "Framework to establish economic level of leakage for intermittent water supplies in arid environments", Journal of Water Resources Planning and Management, 145(2), 1-12.
Hardeman S. (2008). "A cost-benefit analysis of leak detection and the potential of real water savings for New Mexico water systems", Water Resources Professional Project Report Albuquerque, NM: UNM Digital Repository, University of New Mexico.
Islam, M. S. and Babel, M. S. (2013). "Economic analysis of leakage in the Bangkok water distribution system", Journal of Water Resources Planning and Management, 139(2), 209-216.
Kanakoudis, V. and Gonelas, K. (2015). "Estimating the economic leakage level in a water distribution system", Water Resources Management in a Changing World: Challenges and Opportunities, Europan Water Resources Association (EWRA) Publications, Istanbul, Turkey,  1-7.
Kanakoudis, V. and Gonelas, K. (2016). "Non-revenue water reduction through pressure management in Kozani’s water distribution network: from theory to practice", Desalination and Water Treatment, 57(25), 11436-11446.
Kim, E.S., Baek, C.W. and Kim, J.H. (2005). "Estimate of pipe deterioration and optimal scheduling of rehabilitation", Water Science and Technology: Water Supply, 5(2), 39-46.
Kleiner, Y., Adams, B.J. and Rogers, J.S. (1998). "Selection and scheduling of rehabilitation alternatives for water distribution systems", Water Resources Research, 34(8), 2053-2061.
Lambert,  A. and Lalonde,  A. (2005). "Using practical predictions of economic intervention drequency to calculate short-run economic leakage level, with or without pressure management", Proceeding of the IWA Leakage 2005 Conference, Halifax, Nova Scotia, Canada, 1-12.
Lambert, A. and Morrison, J.A.E. (1996). "Recent developments in application of “Bursts and Background Estimates” concepts for leakage management", Journal of International Water and Environmental Management, 10(2), 100-104.
Lambert, A.O., Brown, T.G., Takizawa, M. and Weimer, D. (1999). "A review of performance indicators for real losses from water supply systems", Journal of Water Supply: Research and Technology, AQUA, 48(6), 227-237.
Lambert, A.O. (2002). "International report: Water losses management and techniques", Water Science and Technology: Water Supply, 2(4), 1-20.
Lambert, A.O. and Fantozzi, M. (2005). "Recent advances in calculating economic intervention frequency for active leakage control, and implications for calculation of economic leakage levels", Water Science and Technology: Water Supply, 5(6), 263-271.
Lambert, A.O. and Mckenzie, R. (2001). "Econoleak: Economic model for leakage management for water suppliers in South Africa", Pretoria, Republic of South Africa: South African Water Research Commission, 169(02).
Lambert, A. and Thornton, J. (2012). "Pressure- bursts relationships: Influence of pipe materials, validation of scheme results, and implications of extended asset life", Water Loss 2012, Manila, Philippines, 2-11.
Laucelli, D.B., Simone, A., Berardi, L., Giustolisi, O. (2017). "Optimal design of district metering areas for the reduction of leakages", Journal of Water Resources Planning and Management, 143(6), 04017017.
Lee, H., Kong, M. and Kang, S. (2015). "Economic evaluation of leak monitoring system in water supply system", 99, 71-74.
Li, R., Huang, H., Xin, K., Tao, T. (2015). "A review of methods for burst/leakage detection and location in water distribution systems", Water Science and Technology: Water Supply, 15(3), 429-441.
Frauendorfer, R., Liemberger, R. (2010). "The issues and challenges of reducing non-revenue water", Asian Development Bank, Manila, Philippines.
Liemberger, R., Kingdom, B. and Marin, P. (2006). "The challenge of reducing non-revenue water (NRW) in developing countries", The World Bank, Water Supply and Sanitation Sector Board, PPIAF, 8, 1-40.
Lim, E., Savic, D. and Kapelan, Z. (2015). "Development of a leakage target setting approach for South Korea based on economic level of leakage", Procedia Engineering, 119(1), 120-129.
Lipiwattanakarn, S., Kaewsang, S., Pornprommin, A. and Wongwiset, T. (2019). "Real benefits of leak repair and increasing the number of inlets to energy", Water Science and Technology, 14(3), 714–725.
Loganathan, G.V., Park, S. and Sherali, H.D. (2002). "Threshold break rate for pipeline replacement in water distribution systems", Journal of Water Resources Planning and Management, 128(4), 271-279.
Marchionni, V., Cabral, M., Amado, C. and Covas, D. (2016). "Estimating water supply infrastructure cost using regression techniques", Journal of Water Resources Planning and Management, 142(4), 04016003.
May, J. (1994). "Pressure dependent leakage; world water and environmental engineering", Water Environment Federation: Washington DC, USA.
Mesquita, A.M. and Ruiz, M. (2013). "A financial economic model for urban water pricing in Brazil", Urban Water Journal, 10(2), 85-96.
Molinos-Senante, M., Mocholí-Arce, M. and Sala-Garrido, R. (2016). "Estimating the environmental and resource costs of leakage in water distribution systems: A shadow price approach", Science of the Total Environment, 568, 180-188.
Mondaca, M., Andrade, M.A., Choi, C.Y. and Lansey, K.E. (2015). "Development of a cost function of water distribution systems for residential subdivisions", Urban Water Journal, 12(2), 145-153.
Morrison, J., Tooms, S. and Rogers, D. (2007). District metered areas: Guidance notes, IWA Water Loss Task Force; IWA Publishing: London, UK.
Moslehi, I., Jalili-Ghazizadeh, M., Yousefi-Khoshqalb, E. (2020). "Developing a framework for leakage target setting in water distribution networks from an economic perspective", Structure and Infrastructure Engineering, 17(6), 821-837. 
Moslehi, I., Jalili-Ghazizadeh, M., Yousefi-Khoshqalb, E. (2020). "An economic valuation model for alternative pressure management schemes in water distribution networks", Utilities Policy, 67, 101129.
Muhammetoglu, A., Nursen, C., Karadirek, I.E. and Muhammetoglu, H. (2018). "Evaluation of performance and environmental benefits of a full-scale pump as turbine system in Antalya water distribution network", Water Science and Technology: Water Supply, 18(1), 130-142.
Mutikanga, H.M., Sharma, S.K. and Vairavamoorthy, K. (2013). "Methods and tools for managing losses in water distribution systems", Journal of Water Resources Planning and Management, 139(2), 166-174.
Neelakantan, T.R., Suribabu, C.R. and Lingireddy, S. (2008). "Pipe-sizing optimization including break-repair and replacement economics", Water SA, 34(2), 217-224.
Park, S.W. and Loganathan, G.V. (2002). "Methodology for economically optimal replacement of pipes in water distribution systems: 2. Applications", KSCE Journal of Civil Engineering, 6(4), 545-550.
Pearson, D. and Trow, S.W. (2005). "Calculating the Economic Levels of Leakage", Proceeding of the IWA Leakage 2005 Conference, Halifax, Nova Scotia, Canada, 294-309.
Puust, R., Kapelan, Z., Savic, D.A. and Koppel, T. (2009). "A review of methods for leakage management in pipe networks", Urban Water Journal, 7, 25-45.
Rahman, A. and Wu, Z.Y. (2018). "Multistep simulation-optimization modeling approach for partitioning water distribution system into district meter areas", Journal of Water Resources Planning and Management, 144(5), 04018018.
Rogers, D. and Calvo, B. (2015). "Defining the rehabilitation needs of water networks", Procedia Engineering, 119(1), 182-188.
Romaniuk, M. (2016). "On simulation of maintenance costs for water distribution system with fuzzy parameters", Eksploatacja i Niezawodnosc - Maintenance and Reliability, 18(4), 514-527.
Rudolph, K.U. (2008). "Economic aspects for water loss reduction", International Workshop on Drinking Water Loss Reduction, Developing Capacity for Applying Solutions, 03.-05., September 2008, United Nations University, UN Campus, UNW-DPC, Bonn.
Sarrate, R., Blesa, J., Nejjari, F. and Quevedo, J. (2014). "Sensor placement for leak detection and location in water distribution networks", Water Science and Technology: Water Supply, 14(5), 795-803.
Seago, C.J., McKenzie, R.S. and Liemberger, R. (2005). "International benchmarking of leakage from water reticulation systems", Proceeding of the IWA Leakage 2005 Conference, Halifax, Nova Scotia, Canada, 48-61.
Sechi, G.M. and Zucca, R. (2017). ‘A Cost-Simulation Approach to Finding Economic Optimality in Leakage Reduction for Complex Supply Systems’, Water Resources Management, 31(14), 4601-4615.
Suribabu, C.R. and Neelakantan, T.R. (2012). "Sizing of water distribution pipes based on performance measure and breakage-repair-replacement economics", ISH Journal of Hydraulic Engineering, 18(3), 241-251.
Tabesh, M., Jamasb, M. and Moeini, R. (2011). "Calibration of water distribution hydraulic models: A comparison between pressure dependent and demand driven analyses", Urban Water Journal, 8, 93-102.
Tabesh, M., Yekta, A.H. and Burrows, R. (2008). "An integrated model to evaluate losses in water distribution systems", Water Resources Management, 23, 477-492.
Thornton, J. and Lambert, A.O. (2007). “Pressure management extends infrastructure life and reduces unnecessary energy costs”, IWA Conference Proceedings, Water Loss 2007, Bucharest, Romania, 1-9.
Tricarico, C.  Gargano, R., Kapelan, Z., Savic, D. and De Marinis, G. (2006). "Economic level of reliability for the rehabilitation of hydraulic networks", Civil Engineering and Environmental Systems, 23(3), 191-207.
Venkatesh, G. (2012). "Cost-benefit analysis- leakage reduction by rehabilitating old water pipelines: Case study of Oslo (Norway)", Urban Water Journal, 9(4), 277-286.
Vicente, D.J., Garrote, L., Sánchez, R. and Santillán, D. (2016). "Pressure management in water distribution systems: Current status, proposals, and future trends", Journal of Water Resources Planning and Management, 142(2), 1-13.
Wang, Y., Zayed, T. and Moselhi, O. (2009). "Prediction models for annual break rates of water mains", Journal of Performance of Constructed Facilities, 23(1), 47-54.
Wegelin, W. and McKenzie, R.S. (2010). "Scope for pressure management in South Africa", Proceedings of the IWA Conference ‘Water Loss 2010’, São Paulo, Brazil, 1-5.
Wu, S., Yang, L., Zhou, C. and Zhang, J. (2013). "Analysis of benefits yielded by pressure management in the area based on temperature revision", ICPTT 2013 ASCE, 127-141.
Wu, Z.Y., Sage, P. and Turtle, D. (2010). ‘Pressure-dependent leak detection model and its application to a district water system’, Journal of Water Resources Planning and Management, 136(1), 116-128.
Wyatt, A. and Alshafey, M. (2012). "Non-revenue water: Financial model for optimal management in developing countries", Water Science and Technology: Water Supply, 12(4), 451-463.
Wyatt, A.S. (2010). "Financial model for optimal management of non-revenue water in developing countries", Proceedings of the IWA International Specialised Conference, Water Loss 2010, São Paulo, Brazil, 1-11.
Xin, K., Tao, T., Lu, Y., Xiong, X. and Li, F. (2014). "Apparent losses analysis in district metered areas of water distribution systems", Water Resources Management, 28, 683-696.
Zamenian, H., Mannering, F.L., Abraham, D.M. and Iseley, T., (2017). "Modeling the frequency of water main breaks in water distribution systems: Random-Parameters Negative-Binomial approach", Journal of Infrastructure Systems, 23(2), 04016035.
Zangenehmadar, Z. and Moselhi, O. (2016). "Assessment of remaining useful life of pipelines using different Artificial Neural Networks models", Journal of Performance of Constructed Facilities, 30(5), 04016032.